SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 54
Parameter Description:
ais_gen
The mode used to generate the Alarm Indication Signal (Blue Alarm) taken
from the following table:
ais_gen Description
0 Do not change AIS / Blue alarm generation mode
1 Disabled - do not generate AIS / Blue alarm
2 Enabled - generate AIS / Blue alarm
rai_gen
The mode used to generate the Remote Alarm Indication (Yellow Alarm) taken
from the following table:
rai_gen Description
0 Do not change RAI / Yellow alarm generation mode
1 Disabled - do not generate RAI / Yellow alarm
2 Forced active - generate RAI / Yellow alarm
3 Automatic generation of RAI / Yellow alarm upon loss of
synchronisation
loop_mode
The diagnostic loop back mode taken from the following table:
loop_mode Description
0 Do not change diagnostic loop back mode
1 Disabled - remove any diagnostic loop
2 Payload loopback
3 Remote loopback
4 Local loopback
Zobrazit stránku 53