Welltech SPCI2S Intel NetStructure SS7 Boards Uživatelský manuál Strana 62

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 107
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 61
SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 62
5.3.8 Fixed Data Output Request
Synopsis:
Message sent to the board in order to generate a fixed pattern on a specific E1
/ T1 Line Interface Unit timeslot.
Message Format:
MESSAGE HEADER
FIELD NAME MEANING
type MVD_MSG_SC_FIXDATA (0x7e15)
id
0
src
Sending Module ID
dst MVD_TASK_ID (0x10)
rsp_req
Used to request a confirmation
hclass
0
status
0
err_info
0
len
6
PARAMETER AREA
OFFSET SIZE NAME
0 2 liu_id
2 2 timeslot
4 2 pattern
Description:
This message is sent to the board in order to generate a fixed pattern on a
specific timeslot of an E1 / T1 Line Interface Unit. It is typically issued at
initialisation and whenever a call terminates to generate an IDLE pattern
towards the network.
Parameter Description:
liu_id
The identifier of the E1/T1 Line Interface Unit in the range 0 to one less than
the number of LIUs fitted.
timeslot
The timeslot number on the E1/T1 line interface unit on which the fixed data will
be transmitted. The valid range for timeslot is 1 to 31 for an E1 interface and 1
to 24 for a T1 interface.
Zobrazit stránku 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 106 107

Komentáře k této Příručce

Žádné komentáře